High Quality Room Digital Smart Multi Thermostat Temperature Controller STC-3028

 

Product Paramters
Power supply:AC 110-220V, 50/60Hz / 12VDC / 24VDC
Measurement temperature range:-20°C ~ +80°C
Measuring humidity range:00%RH~+100%RH
Accuracy:±1°C 0.1%RH
Relay output contact capacity:10A
Sensor:Integrated sensor, line length 1 meter
Shell material:gray ABS flame retardant plastic shell
Net weight120g
Gross weight140g
Package Included:1PC x Temperature Controller
Temp/Humidity sensor w/ wire

 

Product Diagram

 

 

STC-3028 Front Display Buttons

 

How to use the Device:

Temperature Setting Instructions

 

Start up temperature<Shutdown temperature= Heating
Start up temperature> Shutdown temperature= Refrigeration

Press Δ 1 to display the starting temperature.

Press and hold Δ1 for about 3 seconds to set start the temperature adjustment (flashing).

You can set the required temperature value by pressing Δ1 and ∇1.

Press ∇1 button once to display the stop temperature.

Press and hold ∇1 for about 3 seconds to set stop the temperature adjustment (flashing).

You can set the desired stop temperature by pressing Δ1 and ∇1.

Humidity Setting Instructions

 

Start up humidity < Shutdown humidity = Humidify
Start up humidity> Shutdown humidity = Dehumidification

Press Δ2 to display the starting humidity.

Press and hold Δ2 for about 3 seconds to start the humidity flashing.

You can set the required humidity value by pressing Δ2 and ∇2.

Press ∇2 button once to display the stop humidity.

Press and hold ∇2 for about 3 seconds to set stop the humidity (flashing).

You can set the desired stop humidity by pressing Δ2 and ∇2.

 

Correcting Temperature and Humidity Readings

 

If the detected temperature deviates from the actual temperature, you can use the procedure below to correct them.

Corrected value = detection value + correction value

press Δ1 and ∇1 at the same time for 3 seconds to display the 0.0 value.

Add or subtract the correc­tion value during this time.

Wait for 5 seconds as the unit will automatically jump back to display the actual temperature.

Temperature and humidity adjustment methods are the same. You’ll just have to use different buttons. The humidity buttons are Δ2 and ∇2.

 

Wiring the Device

 

Note that the temperature and humidity relay terminals are just composed of simple switches. It is not powered, nor does it have a power source.

Internal connection of the STC-3028

 

With this, it’s necessary to include your power sources to the temperature and humidity relay terminals along with your load. See connections below.

STC-3028 Back Wiring

 